Apollo electric fence member set only perimeter 100m x 2 steps
Apollo electric fence member set only perimeter 100m x 2 steps
- 出荷日目安:
- Ships within 3-4 business days
商品説明
Product composition
★A bargain set that includes the posts, wires, and hooks that are necessary when installing an electric fence. 100 meters in circumference x 2 tiers are included as a set.
* Click here to purchase the main unit (power supply).
◯ FRP electric fence post Φ11mm x height 900mm・・・25
◯ Hook insulator for Φ11mm・・・50 pieces
◯ Electric fence wire 200m ... 1 roll
to install an electric fence
To install an electric fence, you need one of the separately sold main body (power supply) sets ( AP-2011 ), this electric wire set (electric fence rope, hook, post), and gate clip.
Main unit (power supply) set
A power supply unit for sending electric shocks, a hazard sign, a grounding bar, an output cable, a main unit mounting bracket, and a voltage detector (tester) are included in the set.
electric wire set
A set includes a rope (electric wire) for transmitting electric shocks, a post for stretching the rope, and a hook.
Example of installation method for each animal
Wild boar countermeasures (two-tiered)
Wild boars have very sensitive noses, so the fence should be placed at the height of the nose. *Even if you try to hit the body, the effect will be diluted.
Drive the post (FRP pole in the figure) 20 to 30 cm into the ground. The standard distance between poles is 200-400cm (adjust according to the terrain). Install two insulators per pole at intervals of 20cm. Connect the connecting lines at intervals of 50 meters.
Measures against deer (4 layers)
Install the fence line at a height where you cannot pass through the lower row and at a height where you cannot jump over the upper row.
Drive the post (FRP pole in the figure) 20 to 30 cm into the ground.
The standard distance between poles is 300-400cm (adjust according to the terrain). Install 4 insulators per pole at intervals of 30 cm. Connect the connecting lines at intervals of 50 meters.
Measures against monkeys (8 columns)
Install it in a position where it cannot jump into, such as a tall tree or a telephone pole. Drive the post (FRP pole in the figure) 20 to 30 cm into the ground.
The standard distance between poles is 300-400cm (adjust according to the terrain). Install 8 insulators per pole at 20cm intervals. Use two connection wires as a pair and connect them at intervals of 50 cm (+ and - are connected at different levels).
Product line-up
Product specifications
FRP電柵支柱 | Φ14mm×高さ900mm 50本 |
---|---|
フック碍子 | Φ14mm用 100個 |
電柵線(長さ) | 200m |