Tiger Wire Set (Strut with Insulator, Wire, Gate Clip, Tester, Winder) 100m x 2 Tier Set
Tiger Wire Set (Strut with Insulator, Wire, Gate Clip, Tester, Winder) 100m x 2 Tier Set
- 出荷日目安:
- Ships within 7 business days
商品説明
Product composition
★This is a great value set that includes posts with insulators, electric wires, gate clips, and a tester that are necessary for installing an electric fence. A set of 100 meters around x 2 tiers is included. * If you want to purchase the main unit (power supply), please click here .
◯ FRP electric fence post Φ16mm x height 930mm・・・50
○Gate clip・・・2 pieces
◯Electric fence rope (stainless steel 6 wires) 200m・・・1 roll
◯Quick tester・・・1 piece
◯ Winder ... 1 piece
to install an electric fence
To install an electric fence, you need the main body (power supply) set (sold separately) and this electric wire set (electric fence rope, post with insulator, gate clip). *Please note that struts, insulators, and gate clips are not compatible with other manufacturers.
Main unit (power supply) set
A power supply unit for sending electric shocks, a hazard sign, a grounding rod, a high-voltage wire, a main unit mounting bracket, and a voltage detector (tester) are included as a set.
electric wire set
The set includes a rope (electric wire) for transmitting electric shocks, a post for stretching the rope, an insulator, and a gate clip to be installed at the entrance.
Example of installation method for each animal
Wild boar countermeasures (two-tiered)
Wild boars have very sensitive noses, so the fence should be placed at the height of the nose. *Even if you try to hit the body, the effect will be diluted.
Drive the post (FRP pole in the figure) 20 to 30 cm into the ground. The approximate distance between poles is 200-400cm (adjust according to the terrain). Install two insulators per pole at intervals of 20cm. Connect the connecting lines at intervals of 50 meters.
Measures against deer (4 layers)
Install the fence line at a height where you cannot pass through the lower row and at a height where you cannot jump over the upper row.
Drive the post (FRP pole in the figure) 20 to 30 cm into the ground.
The standard distance between poles is 300-400cm (adjust according to the terrain). Install 4 insulators per pole at intervals of 30cm. Connect the connecting lines at intervals of 50 meters.
Measures against monkeys (8 columns)
Install it in a position where it cannot jump into, such as a tall tree or a telephone pole. Drive the post (FRP pole in the figure) 20 to 30 cm into the ground.
The standard distance between poles is 300-400cm (adjust according to the terrain). Install 8 insulators per pole at 20cm intervals. Use two connection wires as a pair and connect them at intervals of 50 cm (+ and - are connected at different levels).